Smarten Superb 3075 is a 2.25kW hybrid solar power conditioning unit (PCU) for off-grid applications, PCU has in built 50-ampere advanced maximum power point tracking (MPPT) technology-based charge controller.

 

The solar PCU is designed for commercial spaces and can run a 1-ton inverter technology air-conditioner. Its advanced priority feature allows users to choose between solar, batteries, or grid power. DC-to-AC conversion efficiency is 88%-90%. 

 

  • SELECTABLE 4 levels for battery’s DEPTH OF DISCHARGE
  • 30% MORE EFFICIENT
  • LCD DISPLAY
  • ADVANCED DSP CONTROLLER FOR EFFICIENT WORKING
  • CHARGING FROM MAINS UPTO 90 Volts
  • Voc 35-100V Max Panels Support upto 2000 Watts
  • Able to run 1HP Water Motor Pump (Tested Brands: Lubi, Havells, Kirloskar, Usha etc)
  • Able to run 5 Star inverter AC of 1 to 1.5 Ton Capacity

 

TECHNICAL SPECIFICATIONS

MAINS INPUT MODE  
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery  UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery W.UPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery W.UPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Mains Charging Enable/Disable Yes Provided,you can set by front switch
Frequency Output in Mains Mode Same as input
BATTERY  
Battery Type LA / Tubular / SMF
DC input voltage 24V
Battery Quantity 12V 100Ah to 220Ah 2
Float charging voltage 27.4V±0.2V
Boost charging voltage for LA Battery 28V±0.3V
Boost charging voltage for Tubular and SMF Battery 28.8V±0.3V
Bulk Absorption Battery Voltage 29.6±0.2V
Battery  deep Discharge Recovery Yes (Independent Charger to Recover Deep Discharge Ba  ery)
Mains Charging Current Enable/Disable Yes Provide by Keypad
Charging Current By Grid 15A±3A
BACKUP MODE  
Output voltage 220VAC±10%
Output frequency 50Hz ± 0.2 Hz
Output waveform Pure Sine Wave ≤ 5% THD
No Load current <1.5A
Capacity 3075VA
Discharging current @ full load 90A ± 2A
Low Battery Warning 21.6V±0.2V
Low Battery Cut 20.8V±0.2V
Change over  me UPS mode < 10msec
Change over  me WUPS mode < 25msec
Switching Element MOSFET
Cooling Temp. Controlled Fan
PROTECTIONS  
Overload in backup mode Yes provided, system will indicate on display at 101% load
Short Circuit in Backup Mode System will shutdown a  er 3 - retries in case of output short circuit
Short Circuit in Mains Mode Mains MCB will trip
Back feed System will shutdown in case of back feed and there is no retry
Over  temperature Yes provided, if heat sink temperature goes above 100°C System will shut down
Reverse  Battery DC fuse will blown
Phase to Phase protec on in mains mode Yes provided by electronic
SOLAR CHARGE CONTROLLER  
Solar Charge Controller type MPPT
Max Panel wa  age can be connected 2000WATT
PV Voltage Range 35V - 100±2V
Maximum Battery  current 50Amp.
Efficiency > 93%
Reverse  PV protec on Yes provided, it will also display on LCD panel
Switches Menu (Select),UP,Down,Esc.
Reverse  current flow to PV Yes provided
Sharing of current when PV and Grid Both are available If PV power is not sufficient enough to charge the ba  ery, system will start sharing battery charging from PV and grid.
DOD defination (Depth of Discharge) Mains will be connect when battery voltage reach at defined value of the battery voltage.
DOD  (Depth of Discharge)

20%- if battery voltage is 25.0v±0.2V


30%- if battery voltage is 24.0v±0.2V


40%- if battery voltage is 23.0v±0.2V


50%- if battery voltage is 22.0v±0.2V

Mode Selection

Solar>>Battery>>Grid

Solar>>Grid>>Battery

 Now with Grid Charging Enable / Disable Option
DISPLAY AND ALARMS  
  Welcome, SMARTEN Website Address, System Capacity, Charging Till 90VAC and Deep Discharge Battery,
LCD Initial Display  
  System Setting, UPS / WUPS mode, I/P range 90-295VAC / 170-265VAC, Battery Type Selected LA / SMF / Tubular, DOD.
  Mains ON, Input Voltage, Input Frequency, Battery Voltage, Battery Charging, Battery Charged, Charging Current, Backup Mode, UPS ON, UPS
LCD Status Display OFF, Battery Voltage, Load %, Output Voltage, Output Frequency, Battery Current, PV Current,PV Voltage.
  Mains Low Cut, Mains High Cut, Mains Not Available, Mains Frequency Cut
LCD Fault / Protection Status Display Mains Fuse Blown / MCB Trip, Short Circuit, Overload, Ba  ery Low, High Temperature, Back feed
Buzzer Mains Fuse Blown / MCB Trip, Short Circuit, Overload, Battery Low, High Temperature, Back feed

Made with high-grade quality, technically advanced Superb Solar PCU is an innovative solar inverter, that gives you the joy of an uninterrupted power supply. It has exciting features like LCD Screen, Advanced DSP Controller and more.

Backed by Smarten's impeccable solar panels, the Superb PCU is 30% more efficient than usual PCUs. It comes with 4 levels of battery's depth of discharge options for your different power requirements. With low voltages charging, 10 ms changeover time and triple protection, it completely cancels the need to maintain a separate power backup system for powering equipment.